Kappa Server v5.0.02 – Doc v5.0.02 - © KAPPA 1988-2013
KAPPA Server Guided Session #1 • KSGS01 - 22/38
Detected build up
A node ‘Shut-in indicator’
will appear in the browser. This is a logical function that is 1
when a shut-in is detected, and 0 anywhere else.
E.6.2 • Shut-in express
Once a build-up is tagged within the build-up indicator channel, it is possible to get a quick
look at the corresponding loglog plot in Saphir with just a few clicks.
A shading appears on the build up, since we have selected it.
Click the ‘Shut-in express’ icon
; this is the last option of the ‘Shut-in’ toolbar.
A dialog is displayed to control the transfer of data to Saphir.
Shut-in express called for the main build-up