Emeraude v2.60 – Doc v2.60 - © KAPPA 1988-2010
Guided Interpretati
22
on #9 • B09 - 1/
B09 – Guided Interpretation #9
This session illustrates the workflow offered by Emeraude for Multiple Probes Tools (MPT)
around a Multiple Array Production Suite™ (MAPS) example.
The data comes from a 30° deviated well, logged with a SAT (Spinner Array Tool™), a CAT
(Capacitance Array Tool™) and a RAT (Resistivity Array Tool™). The flow is 3 phases from a
flowing survey. The flowing passes, after a data quality check, will be processed to obtain
average values that will serve as inputs for the PL interpretation.
B09.1 • Loading the Flowing Survey Data
¾
We will start this session by opening the file B09.ke2 which contains the GWD info
(Deviation, GR, ID, Roughness and Perforations) and an empty survey called ‘Flowing’.
¾
In ‘Survey’ tab, click on ‘Information’.
¾
Enter the surface rates: Qw= 0 stb/D; Qo= 4790 stb/D; Qg=17370 Mscf/D.
¾
Load the files B09Up1, B09Up2, B09Up3, B09Down1, B09Down2 and B09Down3.
¾
Define RATDEV and SATDEV mnemonics as deviation.
¾
Be sure to enter up, down and pass numbers as appropriate.
¾
Reset the depth range to view data properly on the screen.
In addition to the combination SAT CAT RAT, the tool string includes a density tool, a
capacitance tool (we will not use it) and two spinners, inline and fullbore. They need to be
defined.
¾
Go to Survey ‘Tool info’, ‘Production Tool String’ tab.
¾
Define the density tool DENR as a nuclear tool.
¾
Enter the CFB blade diameter at 3.5 in and ILS at 1.68 in.
B09.2 • Data Quality Control
The Quality Ccontrol (QC) can be greatly facilitated by displaying the data in an appropriate
way, using view templates.
A view template is a model that allows creating one or several views (user views, image views,
etc…) with predefined settings in a given order. The views resulting from a view template are
created (or displayed if already existing) when the template is invoked. It is not part of this
session to show how a view template can be created and we will use a set of predefined view
templates dedicated to the Sondex tools to generate the displays of interest.