Emeraude v2.60 – Doc v2.60 - © KAPPA 1988-2010
Guided Interpretation #9 • B09 - 15/22
Beware that those additional channels will obviously take some space; this is why for instance the
generation of errors is optional. The averages of the channels representing holdups, rates, and
mixture velocity have been added in the Interpretation input.
A number of new views have been created (and some appeared in the layout up to the usual
limit):
A global error view is created called ‘MPT Errors’ + Interpretation short name. It displays
the overall errors on the reconstructed tools.
A ‘Constraints’ view, indicating how much the constraints are fulfilled.
¾
Use the hide/show view dialog to organize to create the layout with:
[Depth – Z – MPT errors I1 – Constraints - QW_MAPS – QO_MAPS – QG_MAPS – VT_MAPS
– YW_MAPS – YG_MAPS]
¾
Add the corresponding snapshot ‘Processing’.
Fig. B09.15 • ‘Processing’ snapshot
The error view shows that:
The VASPINx are matched with no error; this is normal with the linear model.
The NCAPx are not matched closely when the flow appears to be two-phase.
VAILS and VACFB reconstruction, in the same region of the well, don’t agree with the
measures.
DENR is presenting the same problem.
The ‘Constraints’ view shows how the segregation constraint was honored, 0 being the best
answer.