Emeraude v2.60 – Doc v2.60 - © KAPPA 1988-2010
Guided Interpretation #9 • B09 - 15/22
Beware that those additional channels will obviously take some space; this is why for instance the
generation of errors is optional. The averages of the channels representing holdups, rates, and
mixture velocity have been added in the Interpretation input.
A number of new views have been created (and some appeared in the layout up to the usual
limit):
‐
A global error view is created called ‘MPT Errors’ + Interpretation short name. It displays
the overall errors on the reconstructed tools.
‐
A ‘Constraints’ view, indicating how much the constraints are fulfilled.
¾
Use the hide/show view dialog to organize to create the layout with:
[Depth – Z – MPT errors I1 – Constraints - QW_MAPS – QO_MAPS – QG_MAPS – VT_MAPS
– YW_MAPS – YG_MAPS]
¾
Add the corresponding snapshot ‘Processing’.
Fig. B09.15 • ‘Processing’ snapshot
The error view shows that:
‐
The VASPINx are matched with no error; this is normal with the linear model.
‐
The NCAPx are not matched closely when the flow appears to be two-phase.
‐
VAILS and VACFB reconstruction, in the same region of the well, don’t agree with the
measures.
‐
DENR is presenting the same problem.
The ‘Constraints’ view shows how the segregation constraint was honored, 0 being the best
answer.